Why do Oil & Gas facilities need corrosion control for critical electronics?

Refineries and petrochemical facilities can expose control and electrical systems to corrosive gases, humidity and contaminated outdoor air. These conditions can affect DCS, PLC, SCADA, relay and other electronic systems.

Which areas in an Oil & Gas facility require protection from corrosive gases?

Protection can be required in DCS rooms, central control rooms, electrical rooms, relay rooms, VFD rooms, server rooms and other areas housing critical electronics.

Which corrosive gases are commonly associated with Oil & Gas environments?

Depending on the process and site conditions, contaminants can include H₂S, SO₂, NOₓ, chlorine compounds, VOCs and other reactive gases. A site-specific assessment is required to establish the actual contaminant profile.

How does corrosive air reach a refinery control room?

Contaminated outdoor or process-area air can enter through fresh-air intakes, HVAC systems, doors, building leakage points and other openings. Coastal refineries may also experience salt-laden air in addition to process-related contaminants.

Which Bry-Air GPF system is suitable for a large refinery DCS or control room?

EcoScrub™ Deep Bed is designed for larger control rooms and DCS rooms. Its deep media bed provides high gas-removal capacity and can accommodate multiple media types for environments with more than one corrosive contaminant.

When is a Thin Vertical Bed System more suitable for Oil & Gas applications?

The Thin Vertical Bed System is suited to applications such as smaller control rooms, VFD rooms, relay rooms and LERs where a compact, modular system and easier media changeout are useful, particularly for retrofit applications.

Can one gas-phase filtration system address multiple contaminants in a refinery?

Yes. GPF systems can use different adsorbent and chemically impregnated media, including layered or blended media configurations, to address multiple gaseous contaminants based on the site’s measured contaminant profile.

Can gas-phase filtration help maintain an ISA S71.04 environment in a control room?

Gas-phase filtration can be used as part of a corrosion-control strategy designed around ANSI/ISA S71.04 environmental classification. Monitoring before and after installation helps verify changes in atmospheric corrosivity.

Recommended Products

EcoScrub™ Deep Bed Industrial Air Filtration Systems

EcoScrub™ Deep Bed Industrial Air Filtration Systems

Granular media based corrosive gases and odour removal system (ranging from 500 CFM to 2000 CFM, with higher capacities available on request)

iconview more
EcoScrub™ Thin Bed Systems

EcoScrub™ Thin Bed Systems

Granular media based corrosive and odorous gases removal system (ranging from 500 CFM to 2000 CFM, with higher capacities available on request)

iconview more
Bry-Air Control Room Air Purifier

Bry-Air Control Room Air Purifier

Honeycomb filter based gas phase filtration system (ranging from 500 CFM to 2000 CFM)

iconview more
Honeycomb Chemical Filter – DRISORB™ Series

Honeycomb Chemical Filter – DRISORB™ Series

Macroporous desiccant-based fluted media with low pressure drop

iconview more
BRYSORB™ Chemical Media

BRYSORB™ Chemical Media

Spherical / Cylindrical porous pellets impregnated with proprietary chemicals

iconview more