Our Airgineers Can Help You Select The Right Product!

Contact Us
BryAir

Frequently Asked Questions

Why are bridges prone to corrosion?

Bridges are constantly exposed to moisture and salts from nearby water bodies and the air. In concrete bridges, moisture acts as an electrolyte that corrodes steel reinforcement, which is why bridge corrosion prevention matters for structural integrity.

What are the effects of uncontrolled humidity on bridges?

Regular exposure to the external environment causes oxidation and corrosion, shorter service life, reduced vehicle loading capacity and higher life cycle cost. Unchecked corrosion can lead to costly repairs, safety hazards or structural failure.

What is the root cause of corrosion in bridge steel?

Moisture in the air contacts ferrous metals such as iron and steel used in construction, triggering a chemical reaction that causes rust. This is why moisture must be controlled around steel components.

What humidity and dew point should be maintained to prevent bridge corrosion?

RH should be kept below 40%, with a dew point of -10°C at ambient temperature. This level of dew point corrosion control helps keep the corrosion rate very low.

How are suspension bridge cables protected from corrosion?

Small air gaps between bundled steel wires are continuously fed with dehumidified air, and anchorage rooms are dehumidified to 40% RH. Booster fans maintain airflow, which supports suspension bridge cable protection at the anchorages.

Why choose Bry-Air desiccant dehumidifiers for bridges?

Bry-Air desiccant dehumidifiers maintain a dew point as low as -60°C regardless of ambient conditions. This makes them well suited to preventing corrosion in bridges, including girder bridges where relative humidity inside chambers falls to about 35%.

Recommended Products

Compact Dehumidifiers For Excellent Humidity Control

Compact Desiccant Dehumidifier - FFB Series

CNC fabricated with powder coated finish (ranging from 170 CMH to 4,500 CMH)

view more
Engineered Dehumidifier Front

Industrial Desiccant Dehumidifiers - FLi Series

For complete air handling and environment control needs (ranging from 2,500 CMH to 25,000 CMH)

view more
BryAir

BryGram

Bridges Corrosion

Uncontrolled humidity in bridges lead to oxidation, corrosion, reduced capacity, and increased costs. Moisture during the construction of bridges cause rust in ferrous metals.

HUMIDITY CONTROL DURING BRIDGE CONSTRUCTION

Let's
Get In
Touch

Pahwa Group Logo
Bry Air Logo
DRI Rotors Logo
Delair India Logo
TDS Asia Logo
Pahwa Group Logo
Bry Air Logo
DRI Rotors Logo
Delair India Logo
TDS Asia Logo
Chat With Bry Air On WhatsApp

BryCareTM Support
Online

For assistance, please enter your email and phone number below.
×