AWG APPLICATION NOTES:

DATA CENTERS

Water Availability for Mission-Critical Infrastructure:
THE DATA CENTER WATER CHALLENGE

For a data center, reliable water availability is becoming an increasingly important consideration during site selection, cooling-system design and facility expansion.

While many data centers have access to conventional water sources, some sites face a fundamentally different challenge: there is insufficient water available for the planned cooling requirement, water connections cannot be established, or the use of water for cooling is restricted or prohibited.

In such locations, the question is not simply how to reduce the cost of externally sourced water—it is how to make the site operationally viable when conventional water is not available.

Bry-Air Air Water Generators (AWG) generate water on-site by extracting moisture from ambient air, creating a potential water source for data centers in locations where conventional water availability is limited or unavailable.

AWG can therefore be evaluated not only as a supplementary source, but as an enabling technology for data center sites where securing conventional water is a major constraint.

THE DATA CENTER WATER CHALLENGE

In many locations, access to conventional water is limited, restricted or unavailable, making it a critical challenge for data center development and operations.

No Water Connection
No Water Icon
NO WATER CONNECTION

The site does not have access to a reliable municipal or other conventional water supply.

Water Use Restrictions
WATER USE RESTRICTIONS

Local regulations, water scarcity or site-specific policies restrict the use of conventional water for cooling.

Water Infrastructure Unavailable
Infrastructure Icon
WATER INFRASTRUCTURE UNAVAILABLE

Establishing water infrastructure is difficult, costly or impractical in remote or water-constrained locations.

Arrow

AWG

ON-SITE WATER GENERATION

A RELIABLE SOURCE, INDEPENDENT
OF CONVENTIONAL SUPPLY

Bry-Air AWG extracts moisture from ambient air to generate water on-site, helping enable data centers in water-constrained locations.

WHY SHOULD A DATA CENTER OPERATOR CONSIDER AWG?

01
Make Water-Constrained Sites Viable

Provide a potential on-site water source where conventional water infrastructure is unavailable, inadequate or restricted.

02
Enable Water-Dependent Cooling

Support cooling strategies that require water even when conventional water access cannot be secured.

03
Reduce Dependence on Water Infrastructure

Minimize reliance on municipal connections, tanker logistics or long-distance water transportation.

04
Improve Site Selection Flexibility

Allow operators to evaluate locations where water availability would otherwise limit development or expansion.

05
Build Water Resilience

Provide an additional source of water for critical operations and reduce dependence on a single external supply.

06
Support Future Expansion

Modular AWG systems can be configured and scaled as IT capacity and water requirements increase.

WHAT DETERMINES AWG VIABILITY?

AWG performance is highly dependent on the site's atmospheric conditions and the intended water application. The most important engineering inputs are:

Site / Facility ParameterWhy It Matters
Temperature & Relative HumidityDetermines atmospheric water availability and AWG output
Cooling TechnologyDetermines where and how AWG water can be integrated
Water RequirementEstablishes required generation and storage capacity
Water AvailabilityDetermines whether AWG is being evaluated as a primary, supplementary or resilience source
Water Quality SpecificationDetermines treatment and conditioning requirements
Operating ProfileDetermines daily and annual water demand
Space & InfrastructureDetermines equipment, storage and integration configuration
Redundancy RequirementDefines the required system architecture for mission-critical operations

There is no one-size-fits-all AWG configuration for a data center.

A proper assessment combines the site's climate profile with its actual water requirement, cooling architecture and, critically, the availability and accessibility of conventional water at the site.

AWG AS A SITE-ENABLING WATER SOURCE

Depending on site conditions, AWG can play different roles in a data center's water strategy.

Supplementary Source
SUPPLEMENTARY SOURCE

Where conventional water is available but AWG can supplement existing sources and provide additional resilience.

Conventional Water AWG Water
Resilience Source
Resilience Icon
RESILIENCE SOURCE

Providing additional on-site water availability during periods of supply disruption or restriction.

Conventional Water AWG Water
Primary Source
Primary Icon
PRIMARY SOURCE

Where conventional water is unavailable or cannot support the required application.

Conventional Water AWG Water
Site-Enabling Source
Site-Enabling Icon
SITE-ENABLING SOURCE

Supporting data center development in locations where access to conventional water would otherwise constrain feasibility.

Conventional Water AWG Water
Higher Conventional
Water Availability
Lower Conventional
Water Availability (Higher AWG Importance)

Water Independence Starts Here

From personal units to industrial-scale systems, Bry-Air AWG delivers reliable water generation wherever it is needed.

Talk To Our Experts